Americas
Selective — see noteIndustrial cooling & ventilation for Venezuela
The Valencia and Maracay manufacturing belt, the petrochemical and refining works at Paraguana and Jose, the steel and aluminium plants at Ciudad Guayana and Matanzas and the food and beverage plants around Barquisimeto are tall, hot buildings where the heat is coming off a process rather than only out of the sky. Hammer exhaust fans at up to 68,000 m³/h clear that heat at the wall and HVLS fans keep the floor air moving. Ayzair ships from Pune into Puerto Cabello and La Guaira.
Climate suitability — the honest version
Hot and humid on the coast — 31–34 °C with 70–80% afternoon humidity; Maracaibo hotter still
The Venezuelan coast and the Maracaibo basin are hot and humid, and evaporative cooling is the wrong product for that air. At 70–80% afternoon humidity the wet-bulb depression a cooler needs is simply not there, and the unit would add moisture without delivering much temperature drop. What works in Puerto Cabello, Valencia, Maracaibo and the Guayana works is extraction and air movement: hammer exhaust fans sized to the roof and process heat, and HVLS fans where the building is tall enough to use them. We quote it that way and leave the coolers off.
Puerto Cabello
Primary destination port
35–45 days
Sea transit from India
10–20days
Production lead time
4terms
EXW · FOB · CIF · CFR
The complete range
All six Ayzair families, supplied to Venezuela.
Every product we make is available in Venezuela — thirty-four models across six families. They are ordered here by how well each one suits the local climate and the industries that dominate this market, but nothing is off the list.
Industries
Who buys from us in Venezuela.
Logistics & compliance
Shipping to Venezuela.
| Destination ports | Puerto Cabello · La Guaira |
| Sea transit | 35–45 days from Nhava Sheva, transhipped via a Caribbean or European hub |
| Incoterms | EXW · FOB · CIF · CFR |
| Container loading | 20 ft: up to 90 wall exhaust fans depending on size mix · 40 ft HQ: up to 24 crated HVLS fans |
| Production lead time | 10–20 working days |
- Venezuela runs at 60 Hz, 120/240 V single-phase and 208/480 V three-phase, and this is the single most important technical point on the page. A motor wound for 50 Hz spins roughly 20% faster on a 60 Hz supply. You get more airflow, but you also get more current, a hotter motor, more noise, and bearings and impellers running past the speed they were rated for, because a fan’s absorbed power climbs steeply with speed. We wind motors for 60 Hz when the order states 60 Hz. Put it on the enquiry and it is built correctly; do not plan on connecting a 50 Hz machine as it stands.
- Banking, payment and shipping routes into Venezuela are difficult in practice, and we would rather set that out before you spend time on a specification than after. Confirm with your own bank that the payment route works and with your forwarder that there is a workable sailing and clearance path to Puerto Cabello or La Guaira before placing an order. These are commercial and logistical facts about getting the goods delivered and paid for, and your bank and agent are the right people to confirm them.
- Coastal salt air at Puerto Cabello and La Guaira, and the refinery and petrochemical atmospheres at Paraguana and Jose, are hard on sheet steel and fixings. Specify the marine-grade finish and stainless fasteners at order stage.
- Imported electrical equipment may be subject to local conformity assessment or inspection before shipment. We hold no Venezuelan approval and will not claim one. We supply the complete technical file, motor data and test reports and your agent confirms the current requirement.
Venezuela enquiry
Get a proforma invoice for Venezuela.
Tell us the models and quantities, or just describe the building and let us size it. You will receive USD pricing, your Incoterm, a container loading plan and a confirmed lead time — within one working day.
Export desk
Answers
Supplying Venezuela — common questions
Cannot find what you need? Call +91 80871 10156 or WhatsApp us — an engineer, not a call centre, picks up.
Ask on WhatsAppOur plant is 60 Hz. Does that change the motor?
Yes, and tell us so we build it right. A 50 Hz motor on 60 Hz runs about 20% faster, which raises airflow but also current draw, operating temperature and noise, and pushes bearings and the impeller past their rated speed. We wind for 60 Hz when the order says 60 Hz, which is the correct way to supply this market rather than letting a 50 Hz machine be over-driven in service.
Can evaporative coolers work on the Venezuelan coast?
No. Afternoon humidity at Puerto Cabello, La Guaira and Maracaibo runs 70–80% through the hot season, and evaporative cooling depends on dry air to give a temperature drop. In that air the machine mostly adds moisture. We quote hammer exhaust fans and HVLS fans instead, and we would rather tell you that at enquiry stage.
Can you actually ship to Venezuela at the moment?
Sometimes, and it depends on the routing and the payment path rather than on us. Before we quote seriously, check with your bank that the payment can be made and with your freight forwarder that there is a sailing and a clearance route to Puerto Cabello or La Guaira. If both work we can ship; if either does not, no amount of specification work gets the goods to you, so it is worth settling first.
Next step
Shipping to Venezuela?
Send your requirement and we will confirm the freight route, transit time, landed cost and whether our products genuinely suit your climate — before you commit.