Skip to content
Ayzair

Caribbean & Central America

Selective — see note

Industrial cooling & ventilation for Guatemala

Guatemalan industry concentrates along the CA-9 corridor out of Guatemala City — Zona 12, Villa Nueva, Amatitlán and on down to Escuintla and Puerto Quetzal — with a second cluster around Santo Tomás de Castilla on the Caribbean side. Ayzair supplies HVLS fans, hammer wall exhaust fans and mobile fans to maquila floors, food plants, cement works and coffee mills in those areas. Equipment is built to order so the motor matches Guatemalan supply rather than being adapted after it lands.

Climate suitability — the honest version

32–35 °C on both coastal plains with 70–85% afternoon humidity; a genuine dry season November–April and distinctly drier air in the highlands above 1,500 m

Evaporative cooling is the wrong product for most of Guatemala and we will not sell it as if it were. On the Pacific and Caribbean lowlands afternoon humidity sits at 70–85% for most of the year, which leaves almost no wet-bulb depression to work with — a cooler there adds moisture and very little temperature drop. What does work is moving air and getting roof heat out: HVLS fans where the clear height allows, hammer exhaust fans where it does not. The dry corridor and the highlands are a real exception and we treat them as one.

Puerto Quetzal

Primary destination port

35–45 days

Sea transit from India

10–20days

Production lead time

4terms

EXW · FOB · CIF · CFR

The complete range

All six Ayzair families, supplied to Guatemala.

Every product we make is available in Guatemala — thirty-four models across six families. They are ordered here by how well each one suits the local climate and the industries that dominate this market, but nothing is off the list.

Industrial HVLS Ceiling Fans for Guatemala
Best fit here

HVLS Large Ceiling Fans — DC Energy Saving / AS Series

HVLS (High Volume, Low Speed) fans move massive volumes of air gently across large indoor spaces. One Ayzair fan replaces 10–20 small high-speed fans — cutting energy use by up to 70%.

70 %5–8 °C1,200 m²
Heavy Hammer Exhaust Fans for Guatemala
Strong second

Heavy Hammer Exhaust Fans — Industrial Ventilation

A high-capacity industrial ventilation system designed to expel large volumes of air efficiently — trusted across poultry farms, greenhouses, factories and warehouses.

68,000 m³/h151750 mm
Industrial Mobile Fan — Model 1500 for Guatemala
Also specified

Model 1500 Heavy-Duty Industrial Mobile Fan

A 1.5-metre heavy-duty mobile fan that pushes 38,000 m³/h of directed airflow while drawing just 370 watts — roll it exactly where the heat is.

38,000 m³/h370 W1.5 m
Industrial Portable Air Coolers for Guatemala
Also specified

AYZAIR TENT-150 Industrial Portable Air Cooler

A 150-litre portable evaporative cooler on castor wheels — 16,000 CMH of cooled fresh air covering 1,000 sq ft, on just 500 watts of single-phase power.

16,000 CMH1,000 sq ft150 L
Industrial Duct Air Coolers for Guatemala
Also supplied

Duct air coolers for factories and warehouses

A complete range of industrial duct air coolers - ductable evaporative units that pull fresh outside air, filter and cool it, then push it through ducting to exactly the parts of a factory, warehouse or commercial floor where people actually work.

30,000 CMH1.5–3 kW80–95 %
Inline Duct Fans — Mixed Flow for Guatemala
Also supplied

Inline Duct Fans — Mixed Flow, Ø100 to Ø315

Precision-engineered inline duct fans in high-strength PP — mixed-flow impellers delivering up to 2,300 m³/h and 700 Pa of static pressure across five duct sizes.

052300 m³/h700 Pa

Industries

Who buys from us in Guatemala.

Textiles & apparel maquila
Food processing
Cement & building materials
Coffee milling & processing
Warehousing & port logistics

Logistics & compliance

Shipping to Guatemala.

Destination portsPuerto Quetzal · Santo Tomás de Castilla
Sea transit35–45 days from Nhava Sheva, normally transhipped at Balboa, Manzanillo or Caucedo
IncotermsEXW · FOB · CIF · CFR
Container loading40 ft HQ: HVLS fans ship knocked down at high density · up to 60 coolers
Production lead time10–20 working days
  • Guatemalan supply is 120 V / 240 V single phase and 240 V or 480 V three phase at 60 Hz. A 50 Hz motor run on 60 Hz turns roughly 20% faster — it draws more current, runs hotter and noisier, and the bearings and impeller are not rated for that speed. We wind motors for 60 Hz when the order states it, so tell us the frequency and voltage at enquiry and nothing has to be improvised on site.
  • The Pacific dry corridor and the highlands above 1,500 m do have a real dry season from November to April, and portable evaporative coolers have a narrow seasonal use there. It does not change the verdict for the coast or for year-round plant cooling.
  • Puerto Quetzal handles the Pacific traffic and Santo Tomás de Castilla the Caribbean; tell us which one suits your broker before we book, because the transhipment route and the inland haul differ substantially.

Guatemala enquiry

Get a proforma invoice for Guatemala.

Tell us the models and quantities, or just describe the building and let us size it. You will receive USD pricing, your Incoterm, a container loading plan and a confirmed lead time — within one working day.

Or WhatsApp instantly

We respond within one working day. Your details are used only to prepare your quotation.

Answers

Supplying Guatemala — common questions

Cannot find what you need? Call +91 80871 10156 or WhatsApp us — an engineer, not a call centre, picks up.

Ask on WhatsApp
Would evaporative coolers work in our Escuintla plant?

No, and we would rather say so now. Escuintla sits on the humid Pacific plain where afternoon relative humidity runs 70–85% for most of the year. Evaporative cooling needs dry air to produce a temperature drop; in that humidity you get moisture and noise instead of cooling. HVLS fans and hammer wall exhaust fans are the right answer there, and they cost less to run.

Our shed in Villa Nueva is about 6 m to the roof steel — can we use HVLS fans?

Not well. HVLS fans need 7 m of clear height to develop the floor-level column of air they are designed for; below that the air hits the floor too close to the fan and the coverage collapses. At 6 m we would quote hammer wall exhaust fans to pull heat out of the roof, with mobile Model 1500 fans for spot cooling at workstations.

Do you hold Guatemalan electrical approvals?

We hold no Guatemalan listing and will not claim one. We supply the full technical file — wiring diagrams, motor data, test reports and the CE and IEC documentation we do hold — and your importer or electrical contractor confirms what the local authority requires. If a buyer tells us an approval is expected, we will say plainly whether we can obtain it and what it adds in time and cost.

Next step

Shipping to Guatemala?

Send your requirement and we will confirm the freight route, transit time, landed cost and whether our products genuinely suit your climate — before you commit.

Call nowGet a quote