Skip to content
Ayzair

Europe

Selective — see note

Industrial cooling & ventilation for Netherlands

Two very different Dutch buildings need air moved. The distribution halls around Tilburg, Venlo, Moerdijk and Schiphol run 12–14 m clear and are heated for half the year, with the warm air collecting under the roof where no picker benefits from it. The glasshouses of the Westland and around Venlo need volume flow rather than cooling, which is where the Hammer exhaust range at up to 68,000 m³/h belongs.

Climate suitability — the honest version

Mild and damp — 2–7 °C winters, 22–28 °C summer peaks, humidity usually above 70%

Dutch air is too wet for evaporative cooling and we say so on the quotation. The two honest cases here are winter destratification in the large distribution sheds, where HVLS fans cut gas consumption, and high-volume extract ventilation for glasshouse horticulture, where moving large air volumes cheaply is the whole requirement.

Rotterdam

Primary destination port

22–30 days

Sea transit from India

10–20days

Production lead time

5terms

EXW · FOB · CIF · CFR · DDP on request

The complete range

All six Ayzair families, supplied to Netherlands.

Every product we make is available in Netherlands — thirty-four models across six families. They are ordered here by how well each one suits the local climate and the industries that dominate this market, but nothing is off the list.

Industrial HVLS Ceiling Fans for Netherlands
Best fit here

HVLS Large Ceiling Fans — DC Energy Saving / AS Series

HVLS (High Volume, Low Speed) fans move massive volumes of air gently across large indoor spaces. One Ayzair fan replaces 10–20 small high-speed fans — cutting energy use by up to 70%.

70 %5–8 °C1,200 m²
Heavy Hammer Exhaust Fans for Netherlands
Strong second

Heavy Hammer Exhaust Fans — Industrial Ventilation

A high-capacity industrial ventilation system designed to expel large volumes of air efficiently — trusted across poultry farms, greenhouses, factories and warehouses.

68,000 m³/h151750 mm
Inline Duct Fans — Mixed Flow for Netherlands
Also specified

Inline Duct Fans — Mixed Flow, Ø100 to Ø315

Precision-engineered inline duct fans in high-strength PP — mixed-flow impellers delivering up to 2,300 m³/h and 700 Pa of static pressure across five duct sizes.

052300 m³/h700 Pa
Industrial Duct Air Coolers for Netherlands
Also supplied

Duct air coolers for factories and warehouses

A complete range of industrial duct air coolers - ductable evaporative units that pull fresh outside air, filter and cool it, then push it through ducting to exactly the parts of a factory, warehouse or commercial floor where people actually work.

30,000 CMH1.5–3 kW80–95 %
Industrial Mobile Fan — Model 1500 for Netherlands
Also supplied

Model 1500 Heavy-Duty Industrial Mobile Fan

A 1.5-metre heavy-duty mobile fan that pushes 38,000 m³/h of directed airflow while drawing just 370 watts — roll it exactly where the heat is.

38,000 m³/h370 W1.5 m
Industrial Portable Air Coolers for Netherlands
Also supplied

AYZAIR TENT-150 Industrial Portable Air Cooler

A 150-litre portable evaporative cooler on castor wheels — 16,000 CMH of cooled fresh air covering 1,000 sq ft, on just 500 watts of single-phase power.

16,000 CMH1,000 sq ft150 L

Industries

Who buys from us in Netherlands.

Logistics & distribution centres
Glasshouse horticulture
Food processing & cold chain
Chemicals & port industry
Agricultural machinery
Flower and produce packing halls

Logistics & compliance

Shipping to Netherlands.

Destination portsRotterdam · Amsterdam · Vlissingen
Sea transit22–30 days from Nhava Sheva to Rotterdam, the main European entry port
IncotermsEXW · FOB · CIF · CFR · DDP on request
Container loadingHVLS fans ship knocked down — 20 ft: up to 6 at 24 ft · 40 ft HQ: up to 14
Production lead time10–20 working days
  • Rotterdam is the usual first European call for sailings from Nhava Sheva, so Dutch sites often see the shortest transit in northern Europe and can forward on by barge or truck to Germany and Belgium.
  • 230 V single-phase and 400 V three-phase at 50 Hz matches Dutch supply; no frequency conversion is involved.
  • Venlo-type glasshouses usually have a gutter height of 5–7 m, which is below the 7 m clear height an HVLS fan needs to work properly. For those buildings we quote wall-mounted Hammer exhaust fans, not ceiling fans.
  • CE marking to the Low Voltage and EMC Directives applies to our fans and the declaration of conformity and technical file travel with the shipment.

Netherlands enquiry

Get a proforma invoice for Netherlands.

Tell us the models and quantities, or just describe the building and let us size it. You will receive USD pricing, your Incoterm, a container loading plan and a confirmed lead time — within one working day.

Or WhatsApp instantly

We respond within one working day. Your details are used only to prepare your quotation.

Answers

Supplying Netherlands — common questions

Cannot find what you need? Call +91 80871 10156 or WhatsApp us — an engineer, not a call centre, picks up.

Ask on WhatsApp
Can we use evaporative coolers in a Dutch packing hall?

We would not specify them. Relative humidity here sits above 70% for most of the year and above 80% for much of it, so a wetted pad gives you perhaps one or two degrees while raising the moisture content of air in a building where produce and condensation are already a concern. Extract volume and air movement are the sound answers.

Do the exhaust fans suit glasshouse ventilation?

Yes, and it is one of the few places where our exhaust range is the lead product rather than a supporting one. The Hammer fans run from 200 mm to 1750 mm and up to 68,000 m³/h on 0.15–1.5 kW, which is the right shape for moving bulk air through a glasshouse gable. Tell us the house volume and target air changes per hour and we will size the set.

What does an HVLS fan do in a Dutch distribution centre?

In winter it is a heating measure. A 13 m hall heated to 15 °C at floor level is often 25 °C under the roof, so a quarter or more of the gas burned warms the roof void. Slow downward circulation recovers much of that, commonly 20–30% of heating energy, and it also clears the cold draught band near dock doors. In the few hot weeks of summer the same fan gives a 2–3 °C perceived-temperature benefit from airspeed alone.

Next step

Shipping to Netherlands?

Send your requirement and we will confirm the freight route, transit time, landed cost and whether our products genuinely suit your climate — before you commit.

Call nowGet a quote