Caribbean & Central America
Selective — see noteIndustrial cooling & ventilation for Trinidad and Tobago
The Point Lisas Industrial Estate on the west coast is the largest concentration of heavy industry in the English-speaking Caribbean — ammonia, methanol, iron and steel, and the engineering and fabrication workshops that serve them — with general cargo and warehousing at Port of Spain and energy operations at Point Fortin. Ayzair supplies hammer wall exhaust fans across the 200–1750 mm range into those halls and workshops, HVLS fans where the clear height supports them, and inline duct fans for local extraction. This is the strongest industrial case in the Caribbean and we treat it accordingly.
Climate suitability — the honest version
31–33 °C with 75–85% afternoon humidity year round and a wet season June–December — humid tropical with no genuinely dry month
Evaporative cooling is the wrong product in Trinidad and the humidity figures leave no room to argue it. What makes Trinidad different from every other island in this region is that it has genuine heavy industry. The Point Lisas estate runs ammonia and methanol plants, a steel operation and downstream processing, and those are large hot halls where extraction is not a comfort measure but an operating requirement. Hammer wall exhaust fans in the heavier sizes and HVLS fans in the taller halls are a real technical sale here, not a marginal one.
Point Lisas
Primary destination port
35–45 days
Sea transit from India
10–20days
Production lead time
4terms
EXW · FOB · CIF · CFR
The complete range
All six Ayzair families, supplied to Trinidad and Tobago.
Every product we make is available in Trinidad and Tobago — thirty-four models across six families. They are ordered here by how well each one suits the local climate and the industries that dominate this market, but nothing is off the list.
Industries
Who buys from us in Trinidad and Tobago.
Logistics & compliance
Shipping to Trinidad and Tobago.
| Destination ports | Point Lisas · Port of Spain |
| Sea transit | 35–45 days from Nhava Sheva, transhipped at Caucedo, Kingston or Manzanillo |
| Incoterms | EXW · FOB · CIF · CFR |
| Container loading | 40 ft HQ: large-diameter hammer exhaust fans palletised · HVLS fans knocked down at high density |
| Production lead time | 10–20 working days |
- Trinidad and Tobago runs 115 V / 230 V at 60 Hz, with 400 V or 480 V three phase in industrial premises. A 50 Hz motor spun at 60 Hz turns roughly 20% faster — higher current, more heat and noise, with bearings and impellers not rated for that speed. We wind motors for 60 Hz when the order states it, so confirm frequency and voltage with the enquiry.
- Point Lisas sits on the coast and the air is salt-laden. Specify the coastal duty finish at order stage rather than after the first inspection — it costs little on a new order and a great deal to put right once a standard finish has been in that atmosphere for a season.
- Trinidad lies at about 10 °N, below the main Atlantic hurricane track, and direct strikes are rare compared with the islands to the north. That makes it a steadier shipping destination in the June to November months, and it is sometimes used as a feeder origin for the Windward islands.
- Process plant buyers here work to their own specification documents. We supply motor data, performance curves, sound figures and the CE and IEC certification we hold; we do not hold local or sector approvals and will say so rather than imply otherwise.
Trinidad and Tobago enquiry
Get a proforma invoice for Trinidad and Tobago.
Tell us the models and quantities, or just describe the building and let us size it. You will receive USD pricing, your Incoterm, a container loading plan and a confirmed lead time — within one working day.
Export desk
Answers
Supplying Trinidad and Tobago — common questions
Cannot find what you need? Call +91 80871 10156 or WhatsApp us — an engineer, not a call centre, picks up.
Ask on WhatsAppWhat extraction rate can a single hammer exhaust fan deliver?
The range runs from 200 mm up to 1750 mm across fifteen sizes, with the largest moving up to 68,000 m³/h at 0.15–1.5 kW depending on size and duty. For a process hall the count comes from the air change rate you need against the hall volume and the free area available for make-up air. Send us the hall dimensions, the heat load and where the openings are and we will size it rather than guess.
Is evaporative cooling an option for a Point Lisas workshop?
No. Trinidad is humid in every month, with afternoon relative humidity routinely above 75%, and evaporative cooling needs dry air to work. In a workshop that already has a heat load you would be adding moisture and little else. Extraction is the answer, with HVLS fans over the floor if the hall clears 7 m.
Will standard paint survive at Point Lisas?
Not as long as it should. The estate is coastal and the salt loading is significant. We would specify the coastal duty finish for anything mounted outside or on an exposed elevation, and we would rather discuss that at quotation than have you find out from the first annual inspection.
Next step
Shipping to Trinidad and Tobago?
Send your requirement and we will confirm the freight route, transit time, landed cost and whether our products genuinely suit your climate — before you commit.