Skip to content
Ayzair

Finland

Industrial cooling and ventilation in Tampere

Tampere makes machines, and machine halls are big. Sandvik builds mining and rock drilling equipment here, Valmet supplies paper and board machinery, the cargo handling businesses around Kalmar sit in the same cluster, and around them are fabrication shops, foundries and gear and hydraulic suppliers in Sarankulma, Lielahti, Myllypuro and the Nokia industrial area west of the city. These are not pick and pack sheds. They are 14 to 20 metre bays with overhead cranes, welding stations, paint booths and doors that open onto -15 °C in February. Two consequences follow. Welding fume and solvent from paint work have to be extracted at volume, which is an exhaust fan question with a specific air change target. And the heat that a hall full of process equipment produces all day collects at crane level, where it does nothing for the fitter on the floor. Bringing it back down is the cheapest heating improvement available in a building of that height.

Tampere climate — the honest version

Inland Pirkanmaa is colder than the coast, with January averaging near -8 °C, frequent spells below -20 °C and a heating season running from September to May, while brief summer warmth barely registers against the cost of heating a 16 metre machine hall.

Containers reach Helsinki Vuosaari or Kotka in about 28 to 35 days from Nhava Sheva, then run 180 km north by road to Tampere in a couple of hours, so a delivery cleared in the morning is on site the same day.

6families

Complete range supplied here

34models

Every model available to order

10–20days

Production lead time

24hrs

Sizing and quotation

The complete range

All six Ayzair families, supplied in Tampere.

Every product we make is available in Tampere. They are ordered by how well each one suits the local climate and the industries here, but nothing is off the list.

Industrial HVLS Ceiling Fans supplied in Tampere, Finland
Best fit here

HVLS Large Ceiling Fans — DC Energy Saving / AS Series

HVLS (High Volume, Low Speed) fans move massive volumes of air gently across large indoor spaces. One Ayzair fan replaces 10–20 small high-speed fans — cutting energy use by up to 70%.

70 %5–8 °C1,200
Hammer Exhaust Fans supplied in Tampere, Finland
Strong second

Hammer Exhaust Fans — Heavy-Duty Industrial Ventilation

A high-capacity industrial ventilation system designed to expel large volumes of air efficiently — trusted across poultry farms, greenhouses, factories and warehouses.

68,000 m³/h151750 mm
Mobile Industrial Fan — Model 1500 supplied in Tampere, Finland
Also specified

Model 1500 Heavy-Duty Mobile Industrial Fan

A 1.5-metre heavy-duty mobile fan that pushes 38,000 m³/h of directed airflow while drawing just 370 watts — roll it exactly where the heat is.

38,000 m³/h370 W1.5 m
Industrial Duct Air Coolers supplied in Tampere, Finland
Also supplied

Duct air coolers for factories and warehouses

A complete range of industrial duct air coolers - ductable evaporative units that pull fresh outside air, filter and cool it, then push it through ducting to exactly the parts of a factory, warehouse or commercial floor where people actually work.

30,000 CMH1.5–3 kW80–95 %
Industrial Portable Air Coolers supplied in Tampere, Finland
Also supplied

AYZAIR TENT-150 Industrial Portable Air Cooler

A 150-litre portable evaporative cooler on castor wheels — 16,000 CMH of cooled fresh air covering 1,000 sq ft, on just 500 watts of single-phase power.

16,000 CMH1,000 sq ft150 L
Inline-Jet Mixed-Flow Duct Fans supplied in Tampere, Finland
Also supplied

Inline-Jet Fans — Mixed-Flow Duct Fans, Ø100 to Ø315

Precision-engineered mixed-flow inline fans in high-strength PP — delivering up to 2,300 m³/h and 700 Pa of static pressure across five duct sizes.

052300 m³/h700 Pa

Where we supply

Industrial areas of Tampere.

Sarankulma
Lielahti
Myllypuro industrial area
Nokia industrial zone
Hatanpää
Kolmenkulma
Ylöjärvi industrial estate

Who buys here

Industries in Tampere.

  • Mining and rock drilling equipment
  • Paper and board machinery
  • Cargo handling and lifting equipment
  • Metal fabrication and welding
  • Foundries and forging
  • Hydraulics, gears and components

Worth knowing locally

  • Finnish industrial supply is 400 V three phase 50 Hz and workshop distribution boards in these halls generally have spare capacity for a 1.5 kW fan circuit.
  • EU rules apply, so CE marking with a Machinery Directive declaration and the supporting IEC, LVD and EMC reports are supplied and are what the plant safety engineer records for a fixed installation.
  • Overhead crane runs dictate mounting: fan drop and blade sweep must clear the highest hook position and the crane envelope, so the crane drawing is needed before diameter and drop length are fixed.

Tampere enquiry

Get a proforma invoice for Tampere.

Tell us the building — area, roof height and what happens inside — or name the models and quantities you already know you need. You will get USD pricing, your Incoterm, a container loading plan and a confirmed lead time within one working day.

Or WhatsApp instantly

We respond within one working day. Your details are used only to prepare your quotation.

Answers

Supplying Tampere — common questions

Cannot find what you need? Call +91 80871 10156 or WhatsApp us — an engineer, not a call centre, picks up.

Ask on WhatsApp
How is welding fume extraction sized for a large machine hall?

By air change rate for the welding bay rather than by floor area, since the fume load depends on the number of active stations and the process. In practice a few large wall or gable fans from the 1250 to 1750 mm range give the required volume at lower noise and power than many small units, with make-up air planned so the hall is not put under negative pressure.

Can a fan be fitted in a hall with overhead cranes?

Yes, but the layout has to be worked out first. The fan must sit clear of the crane envelope and the highest hook position, so we work from the crane drawing and the lowest obstruction height. In many Tampere halls this means fans positioned between crane runs or along the bay edges rather than on the centreline.

Why include a mobile industrial fan alongside fixed equipment?

Because heavy fabrication work moves. A fitter welding inside a machine frame or a crew working one assembly for a full shift wants air at that position, not at ceiling level. The 370 W Model 1500 floor fan on wheels covers that duty, is moved by one person, and is often bought in small numbers alongside the fixed installation.

Nearby

Also supplied across Finland.

Next step

Shipping to Tampere?

Send your requirement and we will confirm the freight route, transit time, landed cost and whether our equipment genuinely suits Tampere conditions — before you commit to anything.

Call nowGet a quote